Industry

Cybersecurity for energy facilities

Substations, solar farms, boiler houses and charging stations are controlled remotely – and they are prime targets both in war and for extortionists. CUBRA hides the controls from the internet and lets in only your own dispatcher.

What can happen

A city in darkness within minutes

Energy is attacked by states and criminals – and they know how to do it.

Blackout

Substations are switched off remotely – the city has no power.

No heating

Boiler houses and heating networks stop in winter.

Battery storage fire

An outside command to the battery management system causes overheating.

Hijacked inverters

Monitoring devices become weapons for other attacks.

!
Real cases

2015 and 2016: parts of Ukraine were blacked out remotely. January 2024, Lviv: malware cut heating to 600 buildings for two days.

Where CUBRA Node goes

CUBRA Node at every facility

The CUBRA Node security gateway sits at the substation, plant or boiler house. Control, protection, meters and cameras are kept apart. The dispatcher connects only over our channel.

  • CUBRA Node Edge for remote facilities
  • Speaks the language of energy equipment
  • Your equipment stays as it is
Internetno access to equipmentService companyonly via our channelCUBRA Nodefacility cabinetControldispatcher onlyProtection and relayskept apartMetersmetering onlyCamerasrecorder onlyOfficestaff PCsSegments cannot see each other: a hacked camera cannot reach the controls
What the gateway does

Six levels of protection

Hides it from the internet

There is no way to reach your controls, relays and meters from outside: they cannot be seen from the internet, whatever vulnerabilities they may have.

Splits it into segments

Each group of devices works in its own segment (a separate part of the network): a hacked camera cannot reach the controls.

Lets service in only via our channel

The service company gets in through our secure channel. Every login is logged, and access opens for the duration of the work and closes by itself.

Understands the “language of equipment”

CUBRA Node examines the commands equipment receives over the network: each segment gets only the commands it needs, and the gateway holds back the rest (equipment command filter — after release).

Holds back dangerous commands (after release)

“Switch off all lines at the substation” will not get through silently – the person responsible gets an alarm at once.

Knows every device

CUBRA Node finds all devices, their firmware and known vulnerabilities by itself – and suggests what to do.

Who exactly it is for

Where we help

What is connected and how we handle it
Unit control

The station’s units are controlled over the network. We place them in a closed segment: CUBRA Node lets through only commands from the control system, and holds back unusual ones and raises an alert.

Relay protection

Relay protection disconnects lines in an emergency. We place it in a separate segment with no path at all from the office or the internet; commands come only from the station’s control system.

Equipment manufacturers

Every manufacturer wants to service its equipment remotely. They connect only over our channel and only for the duration of the work; every sign-in is recorded in the log, so there is no permanently open access from outside.

Office

Staff computers sit in a separate segment. Malware most often arrives here by email, but there is no path from this segment to the equipment, so an infected PC will not stop the site from working.

What it protects against
  • Station shutdown
  • Ransomware
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Substations

Substations are controlled remotely from the control room – that is how part of Ukraine was left without power in 2015 and 2016.

What we offer
What is connected and how we handle it
Relays and circuit breakers

Relays and circuit breakers switch lines on and off on the dispatcher’s commands. We place them in a separate segment that accepts commands only from the dispatcher over our channel. CUBRA Node will hold back “Disconnect all lines” and raise an alert.

Meters

Meters send readings to the metering system. We place them in their own segment from which only the metering system is visible; readings cannot be tampered with from another part of the network.

Cameras and security

A camera should send video only to the recorder. We put cameras in a separate segment and hide them from the internet; if a camera tries to scan the network or send data outside, it is isolated and the duty officer gets an alarm.

What it protects against
  • Remote power cut
  • Tampered commands
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Solar and wind farms

Hundreds of inverters and turbine controllers, with the manufacturer’s monitoring over the internet.

What we offer
What is connected and how we handle it
Inverters and turbine controllers

Inverters and controllers manage power generation. We place them in a separate segment and hide them from the internet; they accept commands only from their own dispatcher, so an outside server cannot control the park.

Manufacturer’s monitoring

The manufacturer monitors the equipment over the internet. We let it in only over our channel and only read-only: even if it is taken over, the monitoring cannot control the park or become a foothold for other attacks.

Cameras

A camera should send video only to the recorder. We put cameras in a separate segment and hide them from the internet; if a camera tries to scan the network or send data outside, it is isolated and the duty officer gets an alarm.

What it protects against
  • Inverter takeover
  • Loss of control
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Energy storage

The battery management system monitors temperature and charge. An outside command means overheating and fire.

What we offer
What is connected and how we handle it
Battery management

The management system monitors battery temperature and charge. We place it in a closed segment; CUBRA Node holds back commands that would push the batteries beyond safe limits and raises an alert.

Fire system

The fire system sits in a separate segment: even if someone reaches the battery management, they cannot switch off fire suppression from there.

What it protects against
  • Overheating
  • Fire
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Charging stations

Chargers stand on motorways and in car parks and are controlled from headquarters over the internet.

What we offer
What is connected and how we handle it
Chargers

Chargers are controlled from headquarters over the internet. We connect each one to headquarters only over our channel; it is not visible from the internet, so an outside server cannot change the screen or stop charging.

Payment

The charger’s payment module talks only to the bank; control of the charger is separate. Payments cannot be used to reach the controls, and vice versa.

What it protects against
  • Chargers stopped
  • Someone else’s text on the screens
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Boiler houses and heating networks

Pumps and boilers are controlled remotely. In winter, heating switched off means hundreds of frozen flats.

What we offer
What is connected and how we handle it
Boilers and pumps

Boilers and pumps are controlled remotely from the control room. We place them in a separate segment that accepts only the dispatcher’s commands over our channel. CUBRA Node will hold back an attempt to switch off heating in winter and raise an alert.

Pressure and temperature sensors

Pressure and temperature sensors sit in their own segment. CUBRA Node will notice a sudden, unnatural change in readings and notify the dispatcher.

Cameras

A camera should send video only to the recorder. We put cameras in a separate segment and hide them from the internet; if a camera tries to scan the network or send data outside, it is isolated and the duty officer gets an alarm.

What it protects against
  • Heating cut off
  • Accident
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)
What is connected and how we handle it
Pressure regulators and pumps

Regulators and pumps keep the pressure in the pipe on the dispatcher’s commands. We place them in a closed segment; CUBRA Node holds back commands that would push pressure beyond safe limits and raises an alert.

Control room

The dispatcher controls stations across hundreds of kilometres. Our channel runs to every station, and where there is no internet, CUBRA Offline Gateway takes over, so commands cannot be swapped on the way (CUBRA Offline Gateway — after release).

Office

Staff computers sit in a separate segment. Malware most often arrives here by email, but there is no path from this segment to the equipment, so an infected PC will not stop the site from working.

What it protects against
  • Dangerous pressure
  • Pipeline shutdown
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)

Filling stations

Fuel pumps, tank level sensors and the till are often on one network, and the sensors are visible from the internet.

What we offer
What is connected and how we handle it
Fuel pumps

Fuel pumps sit in a separate segment and accept commands only from the filling station’s till. An outside command to dispense fuel will not get through.

Level sensors

Tank level sensors are often visible from the internet. We place them in their own segment and hide them: data goes only to accounting, and readings cannot be changed from outside.

Payments

A till should talk only to the bank and the accounting system. We put it in a separate segment: there is no path to it from Wi-Fi, cameras or office PCs, and CUBRA Node blocks any other connection the till tries to make.

Customer Wi-Fi

Guests connect to a separate network that offers internet access only. No device on the site is visible from it, so even a guest’s infected phone finds nothing.

What it protects against
  • Tampered readings
  • Card theft
How we connect it
  1. CUBRA Node finds the facility’s equipment by itself
  2. We split control, protection, meters and cameras into segments
  3. We connect the facility to the dispatcher over our channel
  4. We switch on alerts for dangerous commands (after release)
Several sites

All facilities in one dashboard

The control room sees every substation, plant and boiler house. A dangerous command raises an alarm for the duty officer (equipment command filter — after release).

  • The same rules for all sites in one go
  • Alarms sent to the duty officer’s phone
  • Log of service company logins
And people too

Secure communication for staff

Dispatchers, crews and management stay in touch in CUBRA Messenger – even when ordinary communication is down.

  • Messages, calls, mail, files
  • Works on inexpensive phones

FAQ – Energy

How do I protect a substation or solar plant from remote hacking?

Control is hidden from the internet, and commands to relays and inverters are accepted only from your dispatcher. A command to switch off all of a substation’s lines won’t go unnoticed – the dispatcher gets an alert immediately.

Can equipment that has been running for decades be protected?

Yes. CUBRA Node inspects the commands the equipment receives over the network and lets through only the necessary ones. The equipment itself doesn’t need replacing (equipment command filter — after release).

What happens if a site loses its connection?

Protection at the site works independently, and messages between the dispatcher and the site can be sent without internet through CUBRA Offline Gateway (CUBRA Offline Gateway — after release).

How do I connect many remote sites?

Each site has a compact CUBRA Node Edge linked to the centre by a secure channel. All the stations are in one dashboard.

See also: ICS cybersecurity: where to start.