Cybersecurity for data centre and telecom infrastructure

Everyone protects servers, but cooling and power are rarely protected. CUBRA keeps the data centre’s engineering systems and telecom towers apart from everything else.

What can happen

Cooling off – data centre off

The easiest path to the servers runs through the engineering systems.

Cooling

Cooling is switched off – the servers overheat.

Power

UPS units and generators fail to start when the power goes.

Access control

Server room doors open to strangers.

Telecom towers

A whole district without mobile coverage.

!
A real case – 2023

An attack on a major mobile operator in Ukraine left millions of people without service.

Where CUBRA Node goes

A separate “Engineering” segment

The CUBRA Node security gateway separates cooling, power and access control from the server network. On the towers – CUBRA Node Edge.

  • Engineering systems with no path from the server network
  • CUBRA Node Edge on the tower
  • Your equipment stays as it is
Internetno access to equipmentService companyonly via our channelCUBRA Nodedata centreCoolingair conditioningPowerUPS, generatorsAccess controldoors, camerasMonitoringsensorsServerscannot see engineering systemsSegments cannot see each other: a hacked server cannot reach the cooling
What the gateway does

Six levels of protection

Hides it from the internet

There is no way to reach your cooling, power and access control from outside: they cannot be seen from the internet, whatever vulnerabilities they may have.

Splits it into segments

Each group of devices works in its own segment (a separate part of the network): a hacked server cannot reach the cooling.

Lets service in only via our channel

The service company gets in through our secure channel. Every login is logged, and access opens for the duration of the work and closes by itself.

Understands the “language of equipment”

CUBRA Node examines the commands equipment receives over the network: each segment gets only the commands it needs, and the gateway holds back the rest (equipment command filter — after release).

Holds back dangerous commands (after release)

Switching off cooling in a data hall will not get through silently – the person responsible gets an alarm at once.

Knows every device

CUBRA Node finds all devices, their firmware and known vulnerabilities by itself – and suggests what to do.

Who exactly it is for

Where we help

Cooling and UPS

Everyone protects the servers, but cooling and uninterruptible power rarely. Through them, the whole hall can be switched off.

What we offer
What is connected and how we handle it
Air conditioners and chillers

Cooling is connected so engineers can see its status and the hall temperature. We place it in the “Engineering” segment with no path at all from the clients’ server network. CUBRA Node will hold back a command to switch off cooling in the hall and raise an alert.

UPS

UPS units keep the servers powered, and the service company monitors the batteries remotely. We place them in a separate segment; the service company connects only over our channel, and a command to switch off a UPS triggers an alert for the duty officer.

What it protects against
  • Hall overheating
  • Power cut
How we connect it
  1. CUBRA Node finds the engineering systems by itself
  2. We separate cooling, power and access control from the server network
  3. We connect contractors through our channel
  4. We switch on alarms for the duty officer

Generators

A generator must start when the power goes out. If its settings have been quietly changed, it will not start.

What we offer
What is connected and how we handle it
Generator controllers

The controller starts the generator and monitors it, and an engineer sets it up. We place the controllers in a closed segment; settings can be changed only from the engineer’s console, and every change is recorded in the log, so the backup power cannot be quietly “switched off”.

What it protects against
  • Generator fails to start
How we connect it
  1. CUBRA Node finds the engineering systems by itself
  2. We separate cooling, power and access control from the server network
  3. We connect contractors through our channel
  4. We switch on alarms for the duty officer

Mobile phone masts

A tower has power, climate control and site access. Switching them off means leaving a district without communication.

What we offer
What is connected and how we handle it
Power and climate control

The tower’s power and air conditioners are controlled from the operator’s centre. We place them in a separate segment that can be controlled only from the centre over our channel, so an outside command cannot switch the tower off.

Site access

Locks and door sensors show who came to the tower. We place them in a separate segment; opening the cabinet doors without a work order triggers an alert at the centre.

What it protects against
  • District without communication
How we connect it
  1. CUBRA Node finds the engineering systems by itself
  2. We separate cooling, power and access control from the server network
  3. We connect contractors through our channel
  4. We switch on alarms for the duty officer

Operator cabinets

Street cabinets with the provider’s equipment stand unguarded.

What we offer
What is connected and how we handle it
Cabinet equipment

The cabinet equipment serves an entire street and is controlled from the centre. We allow control only from the centre over our channel, and opening the cabinet door triggers an alert, so an outside laptop plugged in on site cannot change anything unnoticed.

What it protects against
  • Street cut off
How we connect it
  1. CUBRA Node finds the engineering systems by itself
  2. We separate cooling, power and access control from the server network
  3. We connect contractors through our channel
  4. We switch on alarms for the duty officer

TV and radio towers

Transmitters are controlled remotely. Hacking them means going on air in someone else’s name.

What we offer
What is connected and how we handle it
Transmitters

A transmitter receives the broadcast programme from the centre. We place it in a closed segment: the programme can be changed only from the centre over our channel, so an outside signal cannot get on air.

What it protects against
  • Hijacked broadcast
How we connect it
  1. CUBRA Node finds the engineering systems by itself
  2. We separate cooling, power and access control from the server network
  3. We connect contractors through our channel
  4. We switch on alarms for the duty officer
Several sites

All sites in one dashboard

The duty officer sees every hall and every tower.

  • The same rules for all sites in one go
  • Alarms sent to the duty officer’s phone
  • Log of service company logins
And people too

Secure communication for staff

Engineers and duty staff stay in touch in CUBRA Messenger – even when the main network is down.

  • Messages, calls, mail, files
  • Works on inexpensive phones

FAQ – Data centres and telecoms

How do I separate data centre infrastructure from the server network?

Cooling, power, UPS units and generators sit in a separate segment with no path from the server network. Switching off a hall’s cooling won’t go unnoticed – the person on duty gets an alert.

Is CUBRA suitable for mobile network towers?

Yes. Each tower has a compact CUBRA Node Edge, and all towers are in one dashboard.

How do I protect access to services from DDoS attacks?

Our own DDoS protection is built into CUBRA Node: unwanted requests are filtered out before processing, and entry points change during an attack (switching entry points under attack — in development).

Does access control work if the external connection goes down?

Yes. Protection and segments work independently inside the site.